material
outer panel
nominal thickness
inner panel
nominal thickness


steel coil
0,63 - 0,88 mm
steel coil
0,63 mm


steel coil
0,6 - 0,7 mm
steel coil
0,63 mm


steel coil
0,50 - 0,75 mm
steel coil
approx. 0,40 mm

outer panel
exterior protection standard

aluminium zinc  alloy, 25 μm to both sides

aluminium zinc  alloy, 25 μm to both sides

aluminium zinc alloy 25 μm

outer panel exterior protection option

both sides galvanised plus outer synthetic coatings

both sides galvanised plus outer synthetic coatings

both sides galvanised plus several outer synthetic coatings

inner panel exterior protection standard

both sides galvanised plus polyester coated

both sides galvanised plus polyester coated

aluzinc or standard colour

exterior roof colour

aluzinc or standard colour

aluzinc or standard colour

standard colour

interior roof colour

Producers standard

Producers standard

Producers standard

exterior panel width
interior panel width


approx. 1.000 mm

approx. 1.000 mm


500 mm

approx. 1.100 mm


1.000 mm

panel length (standard)
with special transport


up to 12.000 mm

up to 16.000 mm


up to 12.000 mm

up to 18.000 mm


up to 12.000 mm

up to 16.000 mm

exterior panel profile
interior panel profile
 

trapezoidal
h = 35 - 50 mm
trapezoidal
h = approx. 20 mm

standing seam
h = 60 mm
trapezoidal
h = approx. 20 mm


Trapezprofil
h = 35 - 50 mm
Trapezprofil
h = 1-3 mm

roof system


ACR 40/0i single skin
ACR 40/30 single skin

ACR 40/60 single skin
ACR 40/80 up to
ACR 40/160 double skin

AER 60/0i single skin
AER 60/30 single skin

AER 60/60 single skin
AER 60/80 up to
AER 60/160 double skin

ASRT 40 Sandwich
ASRT 60 Sandwich
ASRT 80 Sandwich
ASRT 100 Sandwich

ASRT 120 Sandwich

exterior panel fixings

stainless steel self-drilling screws with EPDM washers

secret fix with self sealing standing seam

stainless steel self-drilling screws with EPDM washers

exterior fixings

stainless steel self-drilling screws with EPDM washers

convered fixing with galvanised self-drilling screws

stainless steel self-drilling screws with EPDM washers

interior fixings

galvanised self-drilling screws

galvanised self-drilling screws

stainless steel self-drilling screws

insulation

thickness

mineral-fibre mat with facing

d = 40 up to 160 mm

mineral-fibre mat       with facing

d = 40 up to 160 mm

polyurethane or polyisocyanurate foam 
d = 40 bis 100 mm

thermal conductivity

U =
up to 0,24 (W/m² K)

U =
up to 0,24 (W/m² K)

U =
up to 0,20 (W/m² K)

sound insulation

up to 40 dB, high
sound absorption

up to 40 dB, high sound absorption

up to 25 dB

fire safety

non-flammable fire class A2_s1.do
non-combustable roof

non-flammable fire, class A2_s1.do
non-combustable roof

non-flammable fire, class C_s3. do
non-combustable roof

static calculations

as per local norms

as per local norms

as per local norms

roof edge finishes

identically profiled gutter and verge trim around roof edge

identically profiled gutter and verge trim around roof edge

identically profiled gutter and verge trim around roof edge

accessories

polyester light panels, framing, light bands and roof dome light with smoke and heat operation, ventilators, pipe flashings

framing, light bands and roof dome light with smoke and heat operation, ventilators, pipe flashings

framing, light bands and roof dome light with smoke and heat operation, ventilators, pipe flashings

special options, special constructions

canopies, parapets, build-up roofs, green roofs, etc.

canopies, parapets, build-up roofs, etc.

canopies, parapets, build-up roofs, etc.

quality assurance

as per EN 29001/ISO 9001, continuous external and internal supervision 

approval of DIBt, Berlin, continuous external and internal supervision

approval of DIBt, Berlin, continuous external and internal supervision as well as CE Conformity according to DIN EN 14509